TECHNICAL ARTICLE · MOTOR ENERGY EFFICIENCY · 4Q SYSTEMS

IS 15999 & IS 12615 Motor Testing Standards (India)

What Are IS 15999 and IS 12615? India’s Motor Efficiency Testing and MEPS Standards Explained
KEY TAKEAWAY
IS 15999 and IS 12615 are the two Indian Bureau of Standards (BIS) standards that together govern how electric motors are tested and what efficiency they must achieve in India. IS 15999, equivalent to IEC 60034-2-1, defines the test method. IS 12615, equivalent to IEC 60034-30-1, defines the IE efficiency classification system and the minimum efficiency class required for motors sold in India — currently IE3 mandatory for motors 7.5 kW to 375 kW.

Why 4Q Systems Is Qualified to Explain IS 15999 and IS 12615

This article was written by Guy Fadida and V. Krishnamoorthy, active contributors to IEC TC2 Working Groups responsible for IEC 60034 motor efficiency standards — the international basis of IS 15999 and IS 12615.

  • ■WG28 · Efficiency Methods, IEC 60034-2-1 / IS 15999
  • ■WG31 · Converter-Fed Motors, IEC 60034-2-3
  • ■WG12 · Rotating Machine Testing

Krishnamoorthy serves on BIS ETD 15, the Rotating Machinery Sectional Committee of the Bureau of Indian Standards, the body directly responsible for IS 15999 and IS 12615. 4Q Systems’ 4Q-MEPS platform is designed specifically to automate testing and reporting under both standards.

Introduction: India’s Motor Efficiency Framework

India is one of the world’s largest consumers of electric motors. Three-phase induction motors account for approximately 70% of industrial electricity consumption in the country. Raising motor efficiency by even one IE class — from IE2 to IE3 — delivers significant reductions in energy consumption, operating costs, and carbon emissions at national scale.

To achieve this, India’s Bureau of Indian Standards (BIS) has adopted two complementary standards that together form the backbone of India’s Minimum Energy Performance Standards (MEPS) framework for motors: IS 15999 and IS 12615. Understanding both is essential for motor manufacturers seeking BIS certification, testing laboratories conducting compliance tests, and industrial users specifying motors for purchase.

WHY THIS MATTERS
Both IS 15999 and IS 12615 are technically equivalent to their IEC counterparts. India adopted IEC standards with minimal national deviations, ensuring that motors certified in India meet the same technical requirements as motors certified in the European Union and other IEC-aligned markets.

What Is IS 15999? India’s Motor Efficiency Test Method Standard

IS 15999 is the Indian Standard for determining losses and efficiency of rotating electrical machines. It is technically equivalent to IEC 60034-2-1 and was adopted by the Bureau of Indian Standards to align India’s motor testing methodology with international practice.

IS 15999 defines the following:

  • ■Test methods · procedures for measuring motor efficiency, including input-output methods, the back-to-back / twin-machine method, and calorimetric methods.
  • ■Loss segregation · separation and quantification of stray-load losses, no-load losses, and winding losses.
  • ■Instrument accuracy requirements · Class 0.2 power analysers, NABL-traceable torque transducers, and calibrated speed measurement systems.
  • ■Test conditions · thermal steady state, supply voltage tolerances, frequency tolerances, and ambient temperature recording.
  • ■Uncertainty budgets · methods for calculating and reporting expanded measurement uncertainty, ensuring results are reproducible across laboratories.

In practice, IS 15999 is the standard used by BIS-recognized test laboratories when conducting type testing for BIS Standard Mark certification. A motor manufacturer cannot obtain a BIS licence for IS 12615 without first demonstrating compliance through an IS 15999 test at an approved laboratory.

IS 15999 Test Methods

IS 15999, like IEC 60034-2-1, defines multiple test methods, each suited to different motor sizes and test facility capabilities:

  • ■Method 2-1-1A – Direct input-output · measures electrical input power and mechanical output power (torque × speed) simultaneously. Suitable for all motor sizes and requires a high-accuracy dynamometer.
  • ■Method 2-1-1B – Back-to-back / twin-machine · two identical motors are coupled shaft-to-shaft; one motors while the other regenerates. Only losses need to be supplied. Preferred for large motors above 90 kW and for IE4 testing where uncertainty matters.
  • ■Method 2-1-1C – Calorimetric · measures heat dissipated in a test chamber. High accuracy for small motors below 1 kW and rarely used for industrial motors above 10 kW.
4Q SYSTEMS INSIGHT
4Q Systems’ test facility uses a regenerative dynamometer to implement IS 15999 Methods 2-1-1A and 2-1-1B. The 4Q-MEPS software platform automates the test sequence, records all measurement channels, calculates losses and efficiency, and generates the IS 15999 test report automatically.

4Q Systems regenerative dynamometer test rig configured for IS 15999 and IEC 60034-2-1 motor efficiency testing

Fig. 1 · 4Q Systems regenerative dynamometer test rig configured for IS 15999 / IEC 60034-2-1 efficiency testing of a three-phase induction motor.

What Is IS 12615? India’s Motor Efficiency Class Standard (MEPS)

IS 12615 specifies the minimum efficiency classes and minimum efficiency values for three-phase cage induction motors sold in India. It is technically equivalent to IEC 60034-30-1 and defines the IE efficiency classification system.

IS 12615 covers:

  • ■Motor range · three-phase cage induction motors from 0.37 kW to 375 kW, 2-pole, 4-pole and 6-pole, rated for 50 Hz operation.
  • ■IE efficiency classes · IE2 (High Efficiency), IE3 (Premium Efficiency) and IE4 (Super-Premium Efficiency).
  • ■Minimum efficiency values · tabulated nominal efficiencies (ηN) at 100% rated load for each combination of power, pole number and IE class.
  • ■BIS enforcement · motors placed on the Indian market must carry a BIS Standard Mark (ISI Mark) under IS 12615 and meet the applicable IE class minimum.

The table below shows representative nominal efficiency values from IS 12615 / IEC 60034-30-1 for 4-pole motors operating at 50 Hz. Efficiencies are determined using the test procedures defined by IS 15999 / IEC 60034-2-1.

Source: IS 12615:2018 / IEC 60034-30-1:2014, Table 3 (4-pole, 50 Hz).

Values shown are nominal efficiency (ηN) at 100% rated load.

* IE2 became the minimum efficiency requirement in India from 2018.

The IS 12615 efficiency values represent the minimum performance required for a motor to qualify for a specific IE class. In practice, manufacturers typically design motors to exceed these thresholds by several tenths of a percentage point, providing adequate production tolerance while ensuring consistent compliance during certification testing.

How IS 15999 and IS 12615 Work Together

The two standards are inseparable in practice. IS 15999 is the tool – it defines how to measure efficiency accurately. IS 12615 is the yardstick – it defines what efficiency value the motor must reach to qualify for a given IE class and receive BIS certification.

IS 15999
How to Measure Efficiency
↓
Efficiency Result (ηN)
↓
IS 12615
Required IE Class (IE2 / IE3 / IE4)
↓
BIS Standard Mark Certification
IS 12615 ISI Mark — India Market Access
Fig. 2 · The IS 15999 / IS 12615 / BIS certification pathway for electric motors in India.

Without IS 15999, there would be no reliable, reproducible way to determine whether a motor meets IS 12615 requirements. Without IS 12615, there would be no defined target for the test to evaluate against. A complete motor certification under BIS requires both: a test conducted per IS 15999, producing an efficiency value that is then compared against the IS 12615 minimum for the relevant IE class.

PRACTICAL EXAMPLE
A manufacturer submits a 37 kW, 4-pole motor for IE3 BIS certification. The test laboratory measures efficiency using IS 15999 Method 2-1-1A on a calibrated dynamometer and obtains ηN = 94.1%. IS 12615 requires ηN ≥ 93.9% for IE3, 37 kW, 4-pole, 50 Hz. The motor passes. The BIS licence is issued.

BIS Certification Process Under IS 12615

To sell a three-phase induction motor in India, manufacturers must obtain a BIS Standard Mark licence under IS 12615. The certification process typically involves four stages:

  1. Type Testing – the manufacturer submits motor samples to a BIS-recognised testing laboratory. The laboratory conducts an IS 15999 efficiency test and issues a test report. The report includes measurement data, calibration information, and the calculated efficiency value with an uncertainty statement.
  2. BIS Application – the manufacturer submits the test report, product details, factory information, and application documents to BIS. The submitted results are reviewed against IS 12615 requirements.
  3. Factory Audit – BIS audits the manufacturing facility to verify production quality, process controls, and consistency with the type-tested design.
  4. Licence Grant and Surveillance – when testing and audit requirements are satisfied, BIS grants the Standard Mark licence. Ongoing surveillance and periodic compliance verification continue throughout the licence period.
WHY THIS MATTERS
BIS-recognised laboratories performing IS 15999 and IS 12615 testing must satisfy NABL accreditation requirements. This ensures calibration traceability to national standards and measurement uncertainty within the limits defined by IS 15999, allowing efficiency results to be accepted throughout India’s regulatory framework.

How 4Q Systems Supports IS 15999 and IS 12615 Testing

4Q Systems has developed the 4Q-MEPS automated motor test platform specifically to streamline compliance testing under IS 15999 and IS 12615, and their IEC equivalents. The platform integrates a regenerative dynamometer test rig with proprietary test management software to automate every stage of the efficiency test. 4Q Systems India operations support motor manufacturers across the subcontinent.

The 4Q-MEPS platform supports:

  • ■Automatic efficiency determination · real-time acquisition of input power, shaft torque, and speed. Efficiency is calculated point-by-point with no manual data entry.
  • ■Loss segregation · automated separation of stray-load losses, no-load losses, and winding losses per IS 15999 / IEC 60034-2-1 procedures.
  • ■IE class verification · automatic comparison of measured nominal efficiency against IS 12615 minimum values. Pass/fail status is determined automatically at the conclusion of the test.
  • ■Report generation · IS 15999 test reports generated automatically, including measurement data, calibration references, uncertainty budgets, and IS 12615 IE class declarations.
  • ■Complete test automation · no-load testing, resistance measurement, load-point testing, and temperature-rise evaluation executed automatically with operator supervision only.
  • ■Motor range 0.37 kW to 375 kW · scalable across the complete IS 12615 motor range with 2-, 4-, and 6-pole configurations at 50 Hz.

4Q-MEPS IS 15999 and IEC 60034-2-1 efficiency test report

Fig. 3 · IS 15999 / IEC 60034-2-1 efficiency test report generated by 4Q-MEPS during customer factory acceptance testing.

The 4Q-MEPS platform is used by motor manufacturers in India for both internal quality control and third-party witnessed testing. For manufacturers pursuing BIS certification under IS 12615, 4Q Systems supports witnessed testing programs and assists customers in establishing IS 15999-compliant laboratories with NABL-traceable instrumentation.

Detailed multi-point efficiency data from 4Q Systems factory acceptance test

Fig. 4 · Detailed multi-point efficiency data from a 4Q Systems factory acceptance test. The automated system records all IS 15999-required parameters at each load point.

Why IS 15999 and IS 12615 Matter: Energy and Economic Impact

India’s motor efficiency programme is estimated to avoid approximately 30 TWh of electricity consumption per year as the IE3 mandate takes full effect – equivalent to the annual output of several large power stations. At the motor level, the savings are concrete:

  • ■A 37 kW motor at IE3 vs. IE2 · efficiency improves from approximately 92.7% to 93.9%. For a motor running 6,000 hours per year, annual energy saving is approximately 1,550 kWh. At INR 8/kWh, that is INR 12,400 saved per motor per year.
  • ■A 200 kW motor at IE3 vs. IE2 · efficiency improves from approximately 95.1% to 96.0%. Annual energy saving at 6,000 hours per year is approximately 11,200 kWh — INR 89,600 saved per motor per year.
  • ■An IE4 motor vs. IE3 (75 kW) · an additional efficiency gain of 1.0 percentage point reduces losses by a further 20–25%, delivering additional savings on top of the IE3 baseline.
WHY THIS MATTERS
Beyond energy savings, IS 12615 compliance also supports India’s industrial competitiveness. Motors compliant with IS 12615 IE3 are generally aligned with major international efficiency regulations, facilitating export of Indian-manufactured equipment to global markets and reducing the need for region-specific motor designs.

Frequently Asked Questions

Is IS 15999 the same as IEC 60034-2-1?

Yes – technically equivalent. BIS adopted IEC 60034-2-1 as IS 15999 with minimal national deviations. A motor tested to IEC 60034-2-1 is effectively tested to IS 15999. The same test methods, accuracy requirements, and loss segregation procedures apply. Indian laboratories may refer to either standard, but BIS certification documentation will reference IS 15999.

Is IS 12615 the same as IEC 60034-30-1?

Yes – technically equivalent. IS 12615 adopts IEC 60034-30-1 efficiency class definitions (IE1 through IE4), efficiency values, and motor scope. The primary practical difference is that IS 12615 is enforced by BIS through the Standard Mark (ISI Mark) licensing system, while IEC 60034-30-1 is an international standard adopted by individual country regulations.

Which IE class is mandatory in India as of 2024?

For motors rated 7.5 kW to 375 kW (2-, 4-, or 6-pole, 50 Hz), IE3 is the mandatory minimum under IS 12615:2018, effective from January 2022. For motors below 7.5 kW (down to 0.37 kW), IE2 remains the mandatory minimum. IE4 is currently voluntary in India. Future migration toward IE4 efficiency classes is being discussed internationally and may be considered in future revisions of IS 12615.

Does a motor with a CE Mark (EU) also comply with IS 12615?

Not automatically. A CE-marked motor complying with EU Regulation 2019/1781 will typically meet IS 12615 efficiency values because both regulations are based on IEC 60034-30-1. However, BIS certification requires a separate IS 12615 Standard Mark issued through BIS’s own licensing process, including type testing at a BIS-recognised Indian laboratory. CE marking alone does not satisfy BIS requirements.

What instruments are required for an IS 15999 test?

IS 15999 specifies high-accuracy electrical power measurement, calibrated torque measurement, speed measurement, winding resistance measurement, and temperature measurement for thermal correction. All instruments must have calibration certificates traceable to national standards – in India, this means NABL-accredited calibration.

Can 4Q Systems provide witnessed IS 15999 testing for BIS certification?

Yes. 4Q Systems provides motor efficiency testing services using IS 15999 / IEC 60034-2-1 methodology with NABL-traceable instrumentation. Our 4Q-MEPS platform automates the test sequence and generates compliant test reports.

We support both manufacturer in-house testing, where 4Q-MEPS is installed at the manufacturer’s facility, and witnessed testing programs at IS 15999-compliant facilities. Contact our engineering team to discuss your certification requirements.

Ready for IS 12615 Certification? Start With the Right Test System.

Contact us to discuss BIS certification, motor efficiency testing, or a 4Q-MEPS test system for your facility.

Whether you are a motor manufacturer preparing for BIS IS 12615 certification, a testing laboratory upgrading your IS 15999 test capability, or an industrial buyer verifying supplier compliance, 4Q Systems has the expertise and equipment to support you.

4Q Systems offers:

  • ■IS 15999 / IEC 60034-2-1 compliant testing: automated efficiency measurement from 0.37 kW to 375 kW, 2/4/6 pole, 50 Hz.
  • ■IS 12615 IE class verification: automatic comparison against BIS minimum efficiency values, with pass/fail report.
  • ■4Q-MEPS test platform: for motor manufacturers who want to install automated IS 15999 testing in their own production facility.
  • ■BIS certification support: witnessed testing, test report preparation, and technical guidance through the BIS licensing process.
  • ■IEC TC2 expertise: Guy Fadida and V. Krishnamoorthy bring direct IEC TC2 and BIS ETD 15 standards knowledge to every engagement.
NEED HELP WITH IS 15999 OR IS 12615 COMPLIANCE?
Contact 4Q Systems for:
  • ■Motor efficiency testing solutions (IS 15999 / IEC 60034-2-1)
  • ■BIS IS 12615 certification support
  • ■IE2 / IE3 / IE4 efficiency class verification
  • ■Automated 4Q-MEPS test benches for motor manufacturers

References

  1. IS 15999 (Parts 1 & 2): Methods of Determining Losses and Efficiency of Rotating Electrical Machines. Bureau of Indian Standards, New Delhi. Equivalent to IEC 60034-2-1:2014.
  2. IS 12615:2018: Energy Performance Standards for Three-Phase Induction Motors. Bureau of Indian Standards, New Delhi. Equivalent to IEC 60034-30-1:2014.
  3. IEC 60034-2-1:2014: Rotating electrical machines – Part 2-1: Standard methods for determining losses and efficiency from tests. International Electrotechnical Commission (IEC), Geneva.
  4. IEC 60034-30-1:2014: Rotating electrical machines – Part 30-1: Efficiency classes of line operated AC motors (IE code). International Electrotechnical Commission (IEC), Geneva.
  5. Ministry of Power, Govt. of India: Notification on Energy Efficiency Standards for Three-Phase Induction Motors, 2017 and 2022 amendments.
  6. Bureau of Energy Efficiency (BEE): Star Labelling Programme and MEPS for Industrial Motors. Bureau of Energy Efficiency, Ministry of Power, India.

Related Articles

About the Authors

Written by IEC motor testing specialists and contributors to international motor efficiency standards.

AUTHOR

Guy Fadida

Founder & CTO, 4Q Systems

Guy Fadida is the founder and CTO of 4Q Systems and formerly served as CTO of MEA Testing Systems. He has more than 25 years of experience in motor testing technology, laboratory automation, efficiency measurement, and regenerative dynamometer systems.

From 2012 to 2019 he contributed to IEC TC2 Working Groups responsible for rotating machine testing and motor efficiency measurement, including WG28 (IEC 60034-2-1 Efficiency Methods) and WG31 (Converter-Fed Motors).

His experience includes the design, implementation, and deployment of IEC-compliant motor testing laboratories across Europe, Asia, North America, and the Middle East.

AUTHOR

V. Krishnamoorthy

Technical Advisor & India Partner, 4Q Systems

V. Krishnamoorthy is an active contributor to IEC TC2 Working Groups responsible for rotating machine testing, efficiency methods, and converter-fed motor standards, including WG12, WG28, and WG31.

He also serves on BIS ETD 15, the Rotating Machinery Sectional Committee of the Bureau of Indian Standards (BIS), contributing to the development and implementation of motor testing and efficiency standards throughout India.

With decades of engineering experience, Krishnamoorthy supports manufacturers, certification laboratories, government agencies, and energy-efficiency programs across the region.