4Q-FHD
Precision Motor Characterization Platform
Laboratory-grade hysteresis dynamometer system for motor efficiency analysis, torque characterization, and precision electrical measurements.
01 · PRECISION MOTOR CHARACTERIZATION
Precision Motor Testing and Analysis
The 4Q-FHD is a laboratory-grade hysteresis dynamometer platform for electric motor characterization, efficiency analysis, torque-speed testing, and precision electrical measurements across a wide torque and speed range.
The system combines precision torque measurement, synchronized electrical power analysis, automated PID dynamometer control, and advanced software tools in one compact engineering platform for R&D laboratories, motor validation, and production quality testing.
What It Measures
■Torque and speed
■Input and output power
■Efficiency across the full operating envelope
■Dynamic motor characteristics
■Voltage, current, and power factor
■Temperature – up to 8 channels
4Q-FHD precision hysteresis dynamometer platform for electric motor characterization
4Q-FHD precision hysteresis dynamometer platform with integrated controller and motor fixture.
Key Platform Features
■High-precision hysteresis dynamometer for smooth controllable loading
■Automatic PID control for stable operating-point regulation
■Real-time torque, speed, electrical power, and efficiency analysis
■Industrial-grade hardware for long-term laboratory operation
■Torque measurement accuracy: < ±0.1%
■Speed measurement accuracy: < ±0.2%
■Maximum speed: 20,000 rpm
Supported Motor Technologies
✓Permanent-magnet DC motors
✓Brushless DC motors (BLDC)
✓Permanent-magnet synchronous motors (PMSM)
✓AC induction motors – single-phase and three-phase
✓Switched Reluctance Motor (SRM)
✓Synchronous reluctance motors (SynRM)
✓Servo motors and gear motors
Not Sure Which Precision Dynamometer Fits Your Application?
Speak with 4Q engineers about motor type, torque range, speed requirements, and precision measurement workflows.


Talk With Our Engineers

02 · SYSTEM CONFIGURATION
4Q-FHD System Configuration
Four dynamometer models cover testing from 500 mNm to 10 Nm. All systems share the same software platform, calibration workflow, and DSC1200 control architecture, allowing seamless scaling between R&D and production environments.
ParameterFHD-500mNmFHD-1NmFHD-5NmFHD-10Nm
Max Torque500 mNm1 Nm5 Nm10 Nm
Max Speed20,000 rpm15,000 rpm10,000 rpm10,000 rpm
Continuous Power (5 min)200 W400 W1500 W3000 W
Accuracy0.2% FS0.2% FS0.2% FS0.2% FS
Inertia (kg·m²)2.8×10⁻⁵1.85×10⁻⁴1.85×10⁻³6.3×10⁻³
CoolingAir (internal)Air (internal)Air (internal)Air (internal)
DSC1200 Dynamometer Controller
■Fully synchronized torque, speed, and power acquisition
■USB and Ethernet communication interfaces
■Integrated multi-channel measurement architecture
■Real-time PID dynamometer control
■Industrial-grade hardware for continuous laboratory operation
Integrated Precision Power Analysis
■High-accuracy electrical power measurements
■Voltage and current synchronization with torque and speed
■Multi-channel power analysis architecture
■Support for single-phase and three-phase motors
■High-current measurement capability
■Integrated directly into the 4Q software platform
DSC1200 industrial dynamometer controller used in the 4Q-FHD motor characterization platform
DSC1200 industrial dynamometer controller integrated with the 4Q-FHD platform.
03 · SOFTWARE & CAPABILITIES
Integrated Software and Calibration Workflow
The integrated 4Q software platform combines test execution, calibration, data acquisition, efficiency analysis, and reporting in one synchronized environment.
4Q-FHD software interface showing synchronized motor performance measurements and efficiency analysis
Real-time motor performance analysis – synchronized torque, speed, current, voltage, and efficiency measurements.
Automated sequence test results generated by the 4Q-FHD software platform
Sequence test results table – Torque, Speed, Current, Voltage, PowerIn, PowerOut, and Efficiency per point.
4Q Software Platform
■Real-time graphical monitoring of all measurement channels
■Automated torque-speed and efficiency mapping
■Sequence-based testing and automated report generation
■CSV, Excel, and structured laboratory data export
■User-defined testing profiles and measurement templates
■Multi-language operator interface
Integrated Calibration Workflow
Reliable measurements require traceable calibration. The 4Q-FHD platform includes integrated guided calibration routines for torque, speed, voltage, and current channels.
■Guided torque calibration procedure
■Sensor verification and linearity validation
■Automatic calibration coefficient generation
■Stored calibration history and traceability
The intuitive interface enables operators to configure and execute automated test sequences with minimal setup time. All results are stored automatically and are ready for reporting.
04 · WHY LABORATORIES CHOOSE 4Q-FHD
Why Laboratories Choose 4Q-FHD
Laboratory-Grade Measurement Accuracy
Torque accuracy better than ±0.1% and speed accuracy better than ±0.2%. Fully calibrated measurement chain with synchronized electrical and mechanical acquisition.
Automated Testing Workflow
Automated execution from setup to report generation. Operators configure the test profile once and the platform manages acquisition, stabilization, and data logging automatically.
Wide Motor Technology Coverage
Supports DC, BLDC, PMSM, AC induction, SRM, SynRM, servo motors, and geared motors from 500 mNm to 10 Nm.
Complete Turnkey Platform
Dynamometer, controller, power analysis, calibration workflow, and software platform delivered as one integrated laboratory solution.
Typical Applications
■R&D motor characterization and efficiency analysis
■Speed-torque curve generation and efficiency mapping
■Production quality control and end-of-line motor testing
■University and research laboratory applications
■DC, BLDC, PMSM, and servo motor development
■Small induction motor and geared motor validation
4Q Engineering Experience
■IEC-compliant electric motor testing methodologies
■Custom-configured turnkey laboratory solutions
■Worldwide installation, commissioning, and training support
■Long-term calibration and engineering partnership
4Q-FHD-TestLab
4Q-FHD-1Nm installed in a motor testing laboratory.
TECHNICAL GUIDE

Hysteresis, Eddy-Current or Regenerative Dynamometer?

Not sure a hysteresis dynamometer is the right choice for your motors? Our guide compares the three main dynamometer types: torque at low speed, power range, energy recovery and typical applications.

Read the comparison →

Ready to Start Your Precision Motor Testing Project?
Request a technical quotation for your hysteresis dynamometer system, motor characterization bench, or precision laboratory testing platform.


Request a Technical Quote

info@4Q-Systems.com | +972-9-8655653
4qindia@4Q-Systems.com | +91-9840126476