4Q-MEPS
IEC 60034-2-1 Motor Efficiency Certification System
Turnkey regenerative dynamometer platform for MEPS certification, IEC 60034-2-1 efficiency testing, temperature-rise testing, and laboratory automation.
01 · IEC 60034-2-1 CERTIFICATION SYSTEMS
4Q-MEPS IEC 60034-2-1 Motor Testing & Certification Systems
Turnkey regenerative dynamometer systems for IEC 60034-2-1 motor efficiency testing, MEPS certification, temperature-rise testing, and laboratory automation.
The Hidden Problem
Most MEPS labs are an assembled stack: a dyno from one vendor, a power analyzer from another, and a programmable AC source from a third.
A micro-ohm meter and temperature DAQ sit off to the side. Glue code in LabVIEW or TestStand connects the pieces together.
Every integration point is a place for the test to drift, the calibration to slip, or the auditor to ask hard questions.
What 4Q-MEPS Delivers
■Turnkey IEC 60034-2-1 compliant system
■Single vendor – one PO, one contact, one warranty
■Pre-coded test sequences – no LabVIEW, no scripting
■Calibrated measurement chain end-to-end
■Same software on every stand – calibrate once, repeat
■Regenerative – energy returns to mains, no load bank
“4Q-MEPS is not a dynamometer – it is a complete MEPS Certification Platform with pre-configured IEC 60034-2-1 test sequences and proven field installations.”
Not Sure Which IEC 60034-2-1 Configuration Fits Your Laboratory?
Speak with 4Q engineers about motor power range, test methods, efficiency standards, and laboratory workflows.
02 · REGENERATIVE DYNAMOMETER ARCHITECTURE
Regenerative Dynamometer Architecture
Integrated IEC 60034-2-1 regenerative dynamometer platform with common DC bus architecture, automated power-flow control, and calibrated measurement systems.
4-quadrant regenerative architecture. A common DC bus links the power supply for the MUT and the load drive – energy flows both ways, motoring and braking on the same pass.
The front-end transformer plus active rectifier returns surplus energy to the mains, eliminating the load bank entirely and supplying only the required losses.
The power supply for the MUT carries a VFD, sinus filter, and a step-up auto-transformer so the motor under test always sees clean, scalable variable voltage and frequency (50/60 Hz).
Mechanical coupling between the MUT and load motor runs through a calibrated torque sensor. A single 4Q Software Platform controls the complete stack – power analyser, torque, temperature, and IEC 60034-2-1 automated test sequences.

03 · METHODOLOGY
IEC 60034-2-1 Automated Test Methodology
Automated IEC 60034-2-1 test sequences including temperature-rise testing, stray-load-loss analysis, no-load characterization, load testing, and efficiency certification workflows.
12-Step Test Sequence
■Cold-state R – stator winding resistance at ambient
■Rated-load thermal – run until thermal stability
■Hot R + load curve – six points to 125% rated
■Resistance check between phases
■No-load test – separate iron from F&W losses
■Resistance again – for loss-budget calculations
■Blocked-rotor test – locked-rotor parameters
■Speed-torque curve – full mechanical characteristic
■Momentary overload – breakdown torque check
■Over-speed test – mechanical integrity validation
■V & f variation – supply variation analysis
■VFD efficiency + duty-cycle verification
Auditor-Ready PLL Analysis
Additional load losses – the most demanding calculation in IEC 60034-2-1 – are computed as a residual and smoothed automatically using linear regression algorithms.
Automatic Validation Checks
✓γ ≥ 0.95 enforced – automatic drop & refit if not achieved
✓Target γ ≥ 0.98 with sufficient data points

PLL = A·T² regression per IEC 60034-2-1 § 6.1.3.2.6

4Q-MEPS-S 0.12-7.5 kW

4Q-MEPS-M 7.5-55 kW
04 · REAL OUTPUT · PRODUCT RANGE
From Queue to Curve in Seconds
Automated IEC 60034-2-1 testing workflows with live torque-speed analysis, automated sequencing, and scalable regenerative dynamometer platforms.
Automated IEC 60034-2-1 Test Queue

Automated IEC 60034-2-1 workflow including temperature-rise, no-load, load-curve, and efficiency-test sequencing.
Real-Time Torque-Speed Characterization

Real-time torque-speed curve generation with automated ramp profiles and regenerative load control.
Available Platform Configurations
| Class | Power Range |
|---|---|
| MEPS-S | 0.12 – 7.5 kW |
| MEPS-M | 7.5 – 55 kW |
| MEPS-L | 55 – 375 kW |
Unified software architecture, calibrated regenerative power systems, and identical IEC 60034-2-1 workflows across all platform sizes – from laboratory R&D systems to high-power certification benches up to 375 kW.
05 · SUBMERSIBLE PUMP MOTOR TESTING PLATFORM
4Q-SPTS Submersible Pump Motor Test Platform
Vertical regenerative dynamometer platform for submerged pump motors with controlled thrust loading and real underwater operating simulation.
The 4Q-SPTS platform is designed for vertical testing of submersible pump motors under real operating conditions. The system applies controlled vertical thrust loading to simulate hydraulic and mechanical forces experienced during underwater operation.
Pump motors are fully installed inside a dedicated water tank, enabling true submerged testing for efficiency evaluation, thermal behaviour, endurance validation, vibration analysis, and long-term reliability assessment.
Key Platform Capabilities
Controlled Vertical Thrust Simulation.
Accurately simulates the axial hydraulic and mechanical forces experienced by the pump assembly during real underwater operation.
Accurately simulates the axial hydraulic and mechanical forces experienced by the pump assembly during real underwater operation.
True Submerged Motor Operation.
Motors are fully installed inside a dedicated water tank, delivering realistic thermal and performance behaviour under true submerged conditions.
Motors are fully installed inside a dedicated water tank, delivering realistic thermal and performance behaviour under true submerged conditions.
Real-World Pump Performance Validation.
Measures pump efficiency, thrust behaviour, temperature rise, endurance performance, vibration characteristics, and overall system reliability under real underwater operating conditions.
Measures pump efficiency, thrust behaviour, temperature rise, endurance performance, vibration characteristics, and overall system reliability under real underwater operating conditions.

4Q-SPTS vertical regenerative platform for submerged pump motor validation and thrust-load simulation.

Real submersible pump motors installed for underwater testing applications.
06 · WHY GLOBAL LABS CHOOSE 4Q-MEPS
Why Laboratories Choose 4Q-MEPS
Integrated IEC 60034-2-1 regenerative testing platform with calibrated measurement architecture and pre-coded certification workflows.
IEC 60034-2-1 Methodology Embedded
§ 6.1.3.2.6 codified in software – γ, B, and R² validated automatically with no manual recalculation.
Single Vendor Engineering
One PO, one contact, and one warranty across hardware, software, instrumentation, and installation.
Auditor-Ready Reporting
PDF and CSV reporting workflows aligned with IEC 60034-2-1, NEMA MG1, IEEE 112B, GB18613, and IS12615.
Field-Proven Deployment
Field installations up to 375 kW with pre-integrated regenerative architecture and pre-coded IEC workflows.
Ready to Start Your IEC 60034-2-1 Laboratory Project?
Request a technical quotation for your regenerative dynamometer system, efficiency certification laboratory, or automated motor testing platform.
info@4Q-Systems.com | +972-9-8655653
4qindia@4Q-Systems.com | +91-9840126476









